PuSH - Publikationsserver des Helmholtz Zentrums München

Kampf, C.J.* ; Bonn, B.* ; Hoffmann, T.*

Development and validation of a selective HPLC-ESI-MS/MS method for the quantification of glyoxal and methylglyoxal in atmospheric aerosols (PM2.5).

Anal. Bioanal. Chem. 401, 3115-24 (2011)
DOI PMC
Open Access Green möglich sobald Postprint bei der ZB eingereicht worden ist.
This study concerns the development and validation of a complete method for the analysis of two highly reactive α-dicarbonyl compounds, glyoxal (Gly) and methylglyoxal (Mgly), in atmospheric fine particulate matter (PM(2.5)). Method development included optimization of sample preparation procedures, e.g., filter extraction, concentration of extracts, derivatization and solid-phase extraction (SPE) of derivatives, as well as reversed-phase liquid chromatography coupled to electrospray ion-trap mass spectrometry (HPLC-ESI-IT/MS/MS) measurement parameters. Selectivity of detection was enhanced using tandem mass spectrometric analysis in ESI positive ion mode via two multiple reaction monitoring channels, m/z 433 → m/z 250 and m/z 419 → m/z 236 for Mgly and Gly. Retention times were 9.5 and 12.5 min for Gly- and Mgly-bis-hydrazone derivatives. Calibration ranged from 0.5 to 50 ng/mL. Inter-batch precision, expressed as relative standard deviation, was <15%. The method was shown to be unaffected by the sample matrix and to have recoveries of 100% and 60% for Gly and Mgly, respectively. Improved instrumental detection limits of 0.51 and 0.62 ng/mL for Gly and Mgly were achieved using a SPE method for the purification of 2,4-dinitrophenylhydrazine derivatization reagent solutions. This permitted the method to be used for analysis of filter samples obtained during a field study at the Taunus Observatory (mount Kleiner Feldberg, Germany). PM(2.5) concentrations ranged from 0.81 to 1.18 ng/m(3) for Gly and from 0.83 to 1.92 ng/m(3) for Mgly. PM concentrations correlated to the concentration of NO with coefficients (R(2)) of 0.67 (Gly) and 0.78 (Mgly).
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
3.841
1.211
22
21
Tags
Anmerkungen
Besondere Publikation
Auf Hompepage verbergern

Zusatzinfos bearbeiten
Eigene Tags bearbeiten
Privat
Eigene Anmerkung bearbeiten
Privat
Auf Publikationslisten für
Homepage nicht anzeigen
Als besondere Publikation
markieren
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Sprache englisch
Veröffentlichungsjahr 2011
HGF-Berichtsjahr 0
ISSN (print) / ISBN 1618-2642
e-ISSN 1618-2650
Quellenangaben Band: 401, Heft: 10, Seiten: 3115-24 Artikelnummer: , Supplement: ,
Verlag Springer
Verlagsort Heidelberg
Begutachtungsstatus Peer reviewed
PubMed ID 21725832
Erfassungsdatum 2011-07-03