Open Access Green möglich sobald Postprint bei der ZB eingereicht worden ist.
Iodine removal in intravenous dual-energy CT-cholangiography: Is virtual non-enhanced imaging effective to replace true non-enhanced imaging?
Eur. J. Radiol. 81, 692-699 (2012)
PURPOSE: To evaluate whether virtual non-enhanced imaging (VNI) is effective to replace true non-enhanced imaging (TNI) applying iodine removal in intravenous dual-energy CT-cholangiography. MATERIALS AND METHODS: From April 2009 until February 2010, fifteen potential donors for living-related liver transplantation (mean age 37.6±10.8 years) were included. Potential donors underwent a two-phase CT-examination of the liver. The first phase consisted of a single-energy non-enhanced CT-acquisition that provided TNI. After administration of hepatobiliary contrast agent, the second phase was performed as a dual-energy cholangiographic CT-acquisition. This provided VNI. Objective image quality (attenuation values [bile ducts and liver parenchyma] and contrast-to-noise ratio) and subjective overall image quality (1 - excellent; 5 - non diagnostic) were evaluated. Effective radiation dose was compared. RESULTS: For TNI and VNI, attenuation values for bile ducts were 16.8±11.2HU and 5.5±17.0HU (p<0.05) and for liver parenchyma 55.3±8.4HU and 58.1±10.6HU (n.s.). For TNI and VNI, contrast-to-noise ratio was 2.6±0.6HU and 6.9±2.1HU (p<0.001). For VNI, subjective overall image quality was 1 in ten datasets, 2 in four datasets and 3 in one dataset. Effective radiation dose for the dual-energy cholangiographic CT-acquisition was 3.6±0.9mSv and for two-phase single-energy CT-cholangiography 5.1±1.3mSv (p<0.001). CONCLUSION: In this study on iodine removal in intravenous dual-energy CT-cholangiography, subjective image quality is equivalent, contrast-to-noise ratio is improved and effective radiation dose is reduced when VNI is performed. The differences between TNI and VNI with respect to attenuation values seem to have limited clinical relevance and therefore we consider VNI as effective to replace TNI.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Times Cited
Scopus
Cited By
Cited By
Altmetric
0.000
1.359
11
31
Anmerkungen
Besondere Publikation
Auf Hompepage verbergern
Publikationstyp
Artikel: Journalartikel
Dokumenttyp
Wissenschaftlicher Artikel
Sprache
englisch
Veröffentlichungsjahr
2012
HGF-Berichtsjahr
0
ISSN (print) / ISBN
0720-048X
e-ISSN
0720-048X
Zeitschrift
European Journal of Radiology
Quellenangaben
Band: 81,
Heft: 4,
Seiten: 692-699
Verlag
Elsevier
Begutachtungsstatus
Peer reviewed
Institut(e)
Institute of Pancreatic Islet Research (IPI)
PubMed ID
21353419
Erfassungsdatum
2011-12-31