Halama, A.* ; Kulinski, M.* ; Kader, S.A.* ; Satheesh, N.J.* ; Abou-Samra, A.B.* ; Suhre, K. ; Mohammad, R.M.*

Measurement of 1,5-anhydroglucitol in blood and saliva: From non-targeted metabolomics to biochemical assay.

J. Transl. Med. 14:140 (2016)
Verlagsversion DOI
Open Access Gold
Creative Commons Lizenzvertrag
Background: Diabetes testing using saliva, rather than blood and urine, could facilitate diabetes screening in public spaces. We previously identified 1,5-anhydro-d-glucitol (1,5-AG) in saliva as a diabetes biomarker. The Glycomark (TM) assay kit is FDA approved for 1,5-AG measurement in blood. Here we evaluated its applicability for 1,5-AG quantification in saliva. Methods: Using pooled saliva samples, we validated Glycomark (TM) assay use with a RX Daytona(+) clinical chemistry analyser. We then used this set-up to analyse 82 paired blood and saliva samples from a diabetes case-control study, for which broad mass spectrometry-based characterization of the blood and saliva metabolome was also available. Osmolality was measured to account for potential variability in saliva samples. Results: The technical variability of the read-outs for the pooled saliva samples (CV = 2.05 %) was comparable to that obtained with manufacturer-provided blood surrogate quality controls (CV = 1.38-1.8 %). We found a high correlation between Glycomark assay and mass spectrometry measurements of serum 1,5-AG (r(2) = 0.902), showing reproducibility of the non-targeted metabolomics results. The significant correlation between the osmolality measurements performed at two independent platforms with the time interval of 2 years (r(2) = 0.887), also indicates the sample integrity. The assay read-out for saliva was not correlated with the mass spectrometry-based 1,5-AG saliva measurements. Comparison with the full saliva metabolome revealed a high correlation of the saliva assay read-outs with galactose. Conclusions: Glycomark (TM) assay read-outs for saliva were stable and replicable. However, the signal was dominated by galactose, which is biochemically similar to 1,5-AG and absent in blood. Adapting the 1,5-AG kit for saliva analysis will require enzymatic depletion of galactose. This should be feasible, since the assay already includes a similar step for glucose depletion from blood samples.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
3.694
1.051
19
25
Tags
Anmerkungen
Besondere Publikation
Auf Hompepage verbergern

Zusatzinfos bearbeiten
Eigene Tags bearbeiten
Privat
Eigene Anmerkung bearbeiten
Privat
Auf Publikationslisten für
Homepage nicht anzeigen
Als besondere Publikation
markieren
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Schlagwörter Monitoring Glycemic Control; Tandem Mass-spectrometry; Serum 1,5-anhydroglucitol; Diabetes-mellitus; Determining 1,5-anhydro-d-glucitol; Enzymatic Method; Glucose; Plasma; Marker; Identification
Sprache englisch
Veröffentlichungsjahr 2016
HGF-Berichtsjahr 2016
ISSN (print) / ISBN 1479-5876
e-ISSN 1479-5876
Quellenangaben Band: 14, Heft: 1, Seiten: , Artikelnummer: 140 Supplement: ,
Verlag BioMed Central
Verlagsort London
Begutachtungsstatus Peer reviewed
POF Topic(s) 30505 - New Technologies for Biomedical Discoveries
Forschungsfeld(er) Enabling and Novel Technologies
PSP-Element(e) G-503700-001
Scopus ID 85007614151
Erfassungsdatum 2016-06-15