Non-invasive In-vivo sensing of metabolites with a novel Optoacoustic Spectroscope in the SWIR.
    
    
        
    
    
        
        In: (European Conferences on Biomedical Optics, Munich, Germany). SPIE, 2019. (Proc. SPIE ; 11077)
    
    
    
		
		
			
				In this work we developed a novel near-infrared two-path optoacoustic spectrometer (NiR-TAOS) that could sense OA intensity changes due to metabolite concentration changes in-vivo. The main aim of dividing the optical path in two is 1) perform real time correction of the laser emission profile of the laser source at different wavelengths and, 2) perform pulse to pulse correction to remove laser beam fluctuation and instability to increase signal to noise ratio. Signal to noise ratio improvement was significant not only at spectral peaks, but also at all other wavelengths. The system can be used for broad applications in biomedical measurements such as various metabolites in the SWIR.
			
			
				
			
		 
		
			
				
					
					Impact Factor
					Scopus SNIP
					Web of Science
Times Cited
					Scopus
Cited By
					
					Altmetric
					
				 
				
			 
		 
		
     
    
        Publikationstyp
        Artikel: Konferenzbeitrag
    
 
    
        Dokumenttyp
        
    
 
    
        Typ der Hochschulschrift
        
    
 
    
        Herausgeber
        
    
    
        Schlagwörter
        Near-infrared Two-path Oas ; Non-invasive In-vivo Sensing Of Metabolites ; Optoacoustic ; Sensitivity And Specificity Improvement
    
 
    
        Keywords plus
        
    
 
    
    
        Sprache
        englisch
    
 
    
        Veröffentlichungsjahr
        2019
    
 
    
        Prepublished im Jahr 
        
    
 
    
        HGF-Berichtsjahr
        2019
    
 
    
    
        ISSN (print) / ISBN
        0277-786X
    
 
    
        e-ISSN
        1996-756X
    
 
    
        ISBN
        
    
 
    
        Bandtitel
        
    
 
    
        Konferenztitel
        European Conferences on Biomedical Optics
    
 
	
        Konferzenzdatum
        
    
     
	
        Konferenzort
        Munich, Germany
    
 
	
        Konferenzband
        
    
 
     
		
    
        Quellenangaben
        
	    Band: 11077 
	    Heft: ,  
	    Seiten: ,  
	    Artikelnummer: ,  
	    Supplement: ,  
	
    
 
  
        
            Reihe
            
        
 
        
            Verlag
            SPIE
        
 
        
            Verlagsort
            
        
 
	
        
            Tag d. mündl. Prüfung
            0000-00-00
        
 
        
            Betreuer
            
        
 
        
            Gutachter
            
        
 
        
            Prüfer
            
        
 
        
            Topic
            
        
 
	
        
            Hochschule
            
        
 
        
            Hochschulort
            
        
 
        
            Fakultät
            
        
 
    
        
            Veröffentlichungsdatum
            0000-00-00
        
 
         
        
            Anmeldedatum
            0000-00-00
        
 
        
            Anmelder/Inhaber
            
        
 
        
            weitere Inhaber
            
        
 
        
            Anmeldeland
            
        
 
        
            Priorität
            
        
 
    
        Begutachtungsstatus
        Peer reviewed
    
 
     
    
        POF Topic(s)
        30205 - Bioengineering and Digital Health
    
 
    
        Forschungsfeld(er)
        Enabling and Novel Technologies
    
 
    
        PSP-Element(e)
        G-505500-001
    
 
    
        Förderungen
        
    
 
    
        Copyright
        
    
 	
    
    
    
    
        Erfassungsdatum
        2019-11-11