Magnetic resonance cholangiopancreatography at 3 Tesla: Image quality comparison between 3D compressed sensing and 2D single-shot acquisitions.

Eur. J. Radiol. 115, 53-58 (2019)
DOI PMC
Open Access Green möglich sobald Postprint bei der ZB eingereicht worden ist.
OBJECTIVES: To compare the image quality between compressed sensing (CS) 3D-magnetic resonance cholangiopancreatography (MRCP) using respiratory-triggered (RT) and breath-hold (BH) acquisitions and 2D single-shot breath-hold (SSBH) MRCP at 3 T MRI. METHODS: 53 datasets were retrospectively assessed. 3D-MRCP with CS (RT-CS10, BH-CS24) and 2D-SSBH MRCP were acquired. Overall image quality, blurring/motion artifacts and discernibility of the pancreaticobiliary tree (PBT) structures were scored on a 4-point scale by 2 radiologists. The contrast ratio between the common bile duct and its adjacent tissue was measured by region-of-interest (ROI) analysis. Signal intensity increase at the boundaries of the ducts was quantified by line profiles to objectively characterize blurring and motion artifacts. RESULTS: Total scan duration was 17 s for BH-CS24, 1m12 s for 2D-SSBH and 3m48 s for RT-CS10. Images acquired with CS were consistently rated superior in terms of image quality, background suppression, blurring and discernibility of PBT structures compared to 2D-SSBH images. RT-CS10 was superior to BH-CS24 for all ratings except for blurring. Objective analysis yielded the highest contrast ratio for RT-CS10 (0.91 ± 0.04) followed by BH-C24 (0.88 ± 0.05) and 2D-SSBH (0.85 ± 0.06); one-way ANOVA P < 0.0001. The line-profile slope through the CBD was significantly higher in BH-CS24 (37.91 ± 6.38% of maximum intensity/mm) compared to RT-CS10 (29.46 ± 8.17% of maximum intensity/mm) and on par with 2D-SSBH (35.8 ± 12.30% of maximum intensity/mm); one-way-ANOVA P = 0.017. CONCLUSION: CS allows acquisition of volumetric image data with improved image quality compared to SSBH. CS24 yields substantial gains in acquisition speed while robust towards artifacts, enabling diagnostic image quality with a single breath-hold acquisition.
Impact Factor
Scopus SNIP
Altmetric
2.948
1.170
Tags
Anmerkungen
Besondere Publikation
Auf Hompepage verbergern

Zusatzinfos bearbeiten
Eigene Tags bearbeiten
Privat
Eigene Anmerkung bearbeiten
Privat
Auf Publikationslisten für
Homepage nicht anzeigen
Als besondere Publikation
markieren
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Schlagwörter Biliary Tract ; Diagnostic Techniques And Procedures ; Magnetic Resonance Cholangiopancreatography ; Magnetic Resonance Imaging ; Pancreatic Ducts
Sprache englisch
Veröffentlichungsjahr 2019
HGF-Berichtsjahr 2019
ISSN (print) / ISBN 0720-048X
e-ISSN 0720-048X
Quellenangaben Band: 115, Heft: , Seiten: 53-58 Artikelnummer: , Supplement: ,
Verlag Elsevier
Begutachtungsstatus Peer reviewed
POF Topic(s) 30205 - Bioengineering and Digital Health
Forschungsfeld(er) Enabling and Novel Technologies
PSP-Element(e) G-530014-001
PubMed ID 31084759
Erfassungsdatum 2022-09-13