PuSH - Publikationsserver des Helmholtz Zentrums München

Abdo, M.* ; Kirsten, A.M.* ; von Mutius, E. ; Kopp, M.* ; Hansen, G.* ; Rabe, K.F.* ; Watz, H.* ; Trinkmann, F.* ; Bahmer, T.* ; ALLIANCE study group*

Minimal clinically important difference for impulse oscillometry in adults with asthma.

Eur. Respir. J. 61:2201793 (2023)
Verlagsversion DOI PMC
Open Access Hybrid
Creative Commons Lizenzvertrag
BACKGROUND: Impulse oscillometry (IOS) allows an effort-independent evaluation of small airway function in asthma. Unfortunately, well-determined minimal clinically important differences (MCID) for IOS-measures are lacking. Here, we provide MCIDs for frequently used IOS-measures, namely frequency dependence of resistance (FDR) and area of reactance (AX) in patients with asthma. METHODS: We performed IOS at baseline and 1 year later in adult patients with mild to severe asthma (n=235). In a two-step approach, we first applied a distribution-based method to statistically determine the MCID. Next, we validated the proposed MCID according to patient-reported outcome measures (PROMs) of Asthma Quality of Life Questionnaire (AQLQ), Asthma Control Questionnaire (ACQ) and Asthma Control Test (ACT). We used multivariable analyses to investigate the proposed MCIDs as predictors for improvements in PROMs in comparison to the established MCID of FEV1. RESULTS: The proposed MCID was a decline of≥0.06 kPa·L-1·s-1 and≥0.65 kPa·L-1 for FDR and AX, respectively. Patients who had changes beyond the MCID for both FDR and AX showed greater improvements in all PROMs than those who had not. The mean improvements in PROMs were beyond the established MCID for ACQ and AQLQ and approximated the MCID for ACT score. Multivariable analyses demonstrated the MCID for both FDR and AX as independent predictors for the MCID of all PROMs. The MCID for FDR was a stronger predictor of all PROMs than the MCID for FEV1. CONCLUSION: This study provides MCIDs for IOS-derived measures in adult patients with asthma and emphasizes that small airway function is a distinguished endpoint beyond the conventional measure of FEV1.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
24.300
0.000
3
3
Tags
Anmerkungen
Besondere Publikation
Auf Hompepage verbergern

Zusatzinfos bearbeiten
Eigene Tags bearbeiten
Privat
Eigene Anmerkung bearbeiten
Privat
Auf Publikationslisten für
Homepage nicht anzeigen
Als besondere Publikation
markieren
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Schlagwörter Forced Oscillation Technique; Small Airway Dysfunction; Relevance
Sprache englisch
Veröffentlichungsjahr 2023
HGF-Berichtsjahr 2023
ISSN (print) / ISBN 0903-1936
e-ISSN 1399-3003
Quellenangaben Band: 61, Heft: 5, Seiten: , Artikelnummer: 2201793 Supplement: ,
Verlag European Respiratory Society
Verlagsort Sheffield
Begutachtungsstatus Peer reviewed
Institut(e) Institute of Asthma and Allergy Prevention (IAP)
POF Topic(s) 30202 - Environmental Health
Forschungsfeld(er) Allergy
PSP-Element(e) G-503300-001
Förderungen German Federal Ministry of Education and Research (Bundesministerium fuer Bildung und Forschung (BMBF)
Scopus ID 85159550591
PubMed ID 36758985
Erfassungsdatum 2023-02-23