Warmbrunn, J.* ; Straube, C.* ; Haase, H.U.* ; Sinnecker, D.* ; Laugwitz, K.L.* ; Combs, S.E. ; Schneider, S.* ; Habermehl, D.*
Influence of radiotherapy on cardiac implantable devices and leads-a single-institution analysis and critical evaluation of current guidelines.
Strahlenther. Onkol. 201, 463-471 (2025)
PURPOSE: Increasing life expectancy and advances in cancer treatment will lead to more patients needing both radiation therapy (RT) and cardiac implantable electronic devices (CIEDs). CIEDs, including pacemakers and defibrillators, are essential for managing cardiac arrhythmias and heart failure. Telemetric monitoring of CIEDs checks battery status, lead function, settings, and diagnostic data, thereby identifying software deviations or damage. This study evaluates the German Society for Radiation Oncology (DEGRO)/German Society for Cardiology (DGK) guideline, assessing real-world complications and risk factors and analyzing pacemaker and implantable cardioverter-defibrillator (ICD) lead function for their predictive value concerning device malfunction. METHODS: A total of 54 patients with pacemakers or ICDs who underwent radiation therapy were identified. Demographics, treatment courses, and device information from physical and digital records were extracted. DEGRO/DGK risk groups and pacemaker dependency at the start of RT were assessed. Delineation of the devices and lead insertion sites was performed in the treatment planning system. Dosimetric information from the treatment plans was then correlated with reports of standardized device checks. RESULTS: Over 80% of patients were treated with dual-chamber pacemakers or cardiac resynchronization therapy (CRT), and 16.7% had ICDs. One third of patients were pacemaker dependent. 59.3% of patients were in the low-risk category, 29.3% in the medium-risk, and 11.1% in the high-risk category. Thoracic irradiation resulted in the highest median dose to devices. Lead parameter deviations exceeding thresholds were found in 14.8% for the stimulation threshold and 13.5% for sensing. Device malfunctions occurred in 3.7% of cases, both involving electrical resets and neutron-producing radiation (beam energy 10 megaelectron volt (MV) or higher). CONCLUSION: Collecting lead parameters in addition to secure malfunctions like electrical restarts and memory erasure revealed a significant proportion of treatment courses with temporary changes, though no correlation with individual treatment plans or adverse events was found. The focus on reducing neutron-producing radiation could be further supported.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
Publikationstyp
Artikel: Journalartikel
Dokumenttyp
Wissenschaftlicher Artikel
Typ der Hochschulschrift
Herausgeber
Schlagwörter
Cardiac Implantable Electronic Devices ; Device Malfunctions ; Neutron-producing Radiation ; Pacemaker Dependency ; Radiation Therapy; Degro/dgk-guideline; Latest Generation; Pacemaker; Consensus; Malfunction
Keywords plus
Sprache
englisch
Veröffentlichungsjahr
2025
Prepublished im Jahr
0
HGF-Berichtsjahr
2025
ISSN (print) / ISBN
0179-7158
e-ISSN
1439-099X
ISBN
Bandtitel
Konferenztitel
Konferzenzdatum
Konferenzort
Konferenzband
Quellenangaben
Band: 201,
Heft: 4,
Seiten: 463-471
Artikelnummer: ,
Supplement: ,
Reihe
Verlag
Urban & Vogel
Verlagsort
Tiergartenstrasse 17, D-69121 Heidelberg, Germany
Tag d. mündl. Prüfung
0000-00-00
Betreuer
Gutachter
Prüfer
Topic
Hochschule
Hochschulort
Fakultät
Veröffentlichungsdatum
0000-00-00
Anmeldedatum
0000-00-00
Anmelder/Inhaber
weitere Inhaber
Anmeldeland
Priorität
Begutachtungsstatus
Peer reviewed
POF Topic(s)
30203 - Molecular Targets and Therapies
Forschungsfeld(er)
Radiation Sciences
PSP-Element(e)
G-501300-001
Förderungen
Projekt DEAL
Copyright
Erfassungsdatum
2025-03-19