Tanner, C.* ; Degenhard, A.* ; Schnabel, J.A.* ; Castellano-Smith, A.D.* ; Hayes, C.* ; Sonoda, L.I.* ; Leach, M.O.* ; Hose, D.R.* ; Hill, D.L.G.* ; Hawkes, D.J.*
Comparison of biomechanical breast models: A case study.
Proc. SPIE
4684 III
, 1807-1818 (2002)
DOI
Open Access Green
möglich sobald Postprint bei der ZB eingereicht worden ist.
Abstract
Metriken
Zusatzinfos
We present initial results from evaluating the accuracy with which biomechanical breast models based on finite element methods can predict the displacements of tissue within the breast. We investigate the influence of different tissue elasticity values, Poisson's ratios, boundary conditions, finite element solvers and mesh resolutions on one data set. MR images were acquired before and after compressing a volunteer's breast gently. These images were aligned using a 3D non-rigid registration algorithm. The boundary conditions were derived from the result of the non-rigid registration or by assuming no patient motion at the deep or medial side. Three linear and two non-linear elastic material models were tested. The accuracy of the BBMs was assessed by the Euclidean distance of twelve corresponding anatomical landmarks. Overall, none of the tested material models was obviously superior to another regarding the set of investigated values. A major average error increase was noted for partially inaccurate boundary conditions at high Poisson's ratios due to introduced volume change. Maximal errors remained, however, high for low Poisson's ratio due to the landmarks closeness to the inaccurate boundary conditions. The choice of finite element solver or mesh resolution had almost no effect on the performance outcome. © 2002 SPIE · 1605-7422/02/$15.00.
Altmetric
Weitere Metriken?
[➜Einloggen]
Tags
Anmerkungen
Besondere Publikation
Zusatzinfos bearbeiten
[➜Einloggen]
Publikationstyp
Artikel: Journalartikel
Dokumenttyp
Wissenschaftlicher Artikel
Typ der Hochschulschrift
Herausgeber
Korrespondenzautor
Schlagwörter
Biomechanical Models ; Breast Deformation ; Finite Element Methods ; Non-rigid Registration
Keywords plus
ISSN (print) / ISBN
0277-786X
e-ISSN
1996-756X
ISBN
Bandtitel
Konferenztitel
Konferzenzdatum
Konferenzort
Konferenzband
Zeitschrift
Proceedings of SPIE
Quellenangaben
Band: 4684 III,
Heft: ,
Seiten: 1807-1818
Artikelnummer: ,
Supplement: ,
Reihe
Verlag
SPIE
Verlagsort
Hochschule
Hochschulort
Fakultät
Veröffentlichungsdatum
0000-00-00
Veröffentlichungsnummer
Anmeldedatum
0000-00-00
Anmelder/Inhaber
weitere Inhaber
Anmeldeland
Priorität
Nichtpatentliteratur
Publikationen
Begutachtungsstatus
Peer reviewed
Institut(e)
Institute for Machine Learning in Biomed Imaging (IML)
Förderungen
Copyright