Schmidt, S.* ; Li, W.* ; Schubert, M.* ; Binnewerg, B.* ; Prönnecke, C.* ; Zitzmann, F.D.* ; Bulst, M.* ; Wegner, S.* ; Meier, M. ; Guan, K.* ; Jahnke, H.G.*
Novel high-dense microelectrode array based multimodal bioelectronic monitoring system for cardiac arrhythmia re-entry analysis.
Biosens. Bioelectron. 252:116120 (2024)
In recent decades, significant progress has been made in the treatment of heart diseases, particularly in the field of personalized medicine. Despite the development of genetic tests, phenotyping and risk stratification are performed based on clinical findings and invasive in vivo techniques, such as stimulation conduction mapping techniques and programmed ventricular pacing. Consequently, label-free non-invasive in vitro functional analysis systems are urgently needed for more accurate and effective in vitro risk stratification, model-based therapy planning, and clinical safety profile evaluation of drugs. To overcome these limitations, a novel multilayer high-density microelectrode array (HD-MEA), with an optimized configuration of 512 sensing and 4 pacing electrodes on a sensor area of 100 mm2, was developed for the bioelectronic detection of re-entry arrhythmia patterns. Together with a co-developed front-end, we monitored label-free and in parallel cardiac electrophysiology based on field potential monitoring and mechanical contraction using impedance spectroscopy at the same microelectrode. In proof of principle experiments, human induced pluripotent stem cell (hiPS)-derived cardiomyocytes were cultured on HD-MEAs and used to demonstrate the sensitive quantification of contraction strength modulation by cardioactive drugs such as blebbistatin (IC50 = 4.2 μM), omecamtiv and levosimendan. Strikingly, arrhythmia-typical rotor patterns (re-entry) can be induced by optimized electrical stimulation sequences and detected with high spatial resolution. Therefore, we provide a novel cardiac re-entry analysis system as a promising reference point for diagnostic approaches based on in vitro assays using patient-specific hiPS-derived cardiomyocytes.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
Publikationstyp
Artikel: Journalartikel
Dokumenttyp
Wissenschaftlicher Artikel
Typ der Hochschulschrift
Herausgeber
Schlagwörter
Electrical Stimulator-based Pacing ; Field Potential Monitoring ; Impedimetric Contraction Strength Monitoring ; Large-area Microelectrode Array ; Rotor Pattern Detection; Cardiomyocytes; Blebbistatin; Levosimendan; Tissue; Cells
Keywords plus
Sprache
englisch
Veröffentlichungsjahr
2024
Prepublished im Jahr
0
HGF-Berichtsjahr
2024
ISSN (print) / ISBN
0956-5663
e-ISSN
1873-4235
ISBN
Bandtitel
Konferenztitel
Konferzenzdatum
Konferenzort
Konferenzband
Quellenangaben
Band: 252,
Heft: ,
Seiten: ,
Artikelnummer: 116120
Supplement: ,
Reihe
Verlag
Elsevier
Verlagsort
Oxford Fulfillment Centre The Boulevard, Langford Lane, Kidlington, Oxford Ox5 1gb, Oxon, England
Tag d. mündl. Prüfung
0000-00-00
Betreuer
Gutachter
Prüfer
Topic
Hochschule
Hochschulort
Fakultät
Veröffentlichungsdatum
0000-00-00
Anmeldedatum
0000-00-00
Anmelder/Inhaber
weitere Inhaber
Anmeldeland
Priorität
Begutachtungsstatus
Peer reviewed
Institut(e)
Helmholtz Pioneer Campus (HPC)
POF Topic(s)
30201 - Metabolic Health
Forschungsfeld(er)
Pioneer Campus
PSP-Element(e)
G-510002-001
Förderungen
European Union (EFRE)
Saxon Ministry of Science and the Fine Arts (SMWK)
Copyright
Erfassungsdatum
2024-04-24