PuSH - Publication Server of Helmholtz Zentrum München

Simulation of OSL and TLD dosemeter response for the development of new extremity dosemeters.

Radiat. Prot. Dosim. 185, 222-230 (2019)
Postprint DOI PMC
Open Access Green
The individual monitoring service at the Helmholtz Zentrum Munchen is currently developing a new eye lens dosemeter to be integrated in radiation protection glasses and a new ring dosemeter using a new BeOSL detector element for extremity dosimetry developed by Dosimetrics. In the design process for the new eye lens dosemeter, MCNP6 Monte Carlo simulations were used to model the energy and angular response of new dosemeters before ordering the expensive tools for injection molding. This study describes the simulation of the dosemeter and detector, and the involved calculations do obtain the response in terms of the radiation protection quantity H-p(3). Simulations were carried out also for existing whole body dosemeters and TLD rings in order to verify the MC tools. With the final dosemeter prototypes becoming available earlier this year, all MC models could be verified and show very good agreement with experimental data.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
0.831
0.687
6
7
Tags
Annotations
Special Publikation
Hide on homepage

Edit extra information
Edit own tags
Private
Edit own annotation
Private
Hide on publication lists
on hompage
Mark as special
publikation
Publication type Article: Journal article
Document type Scientific Article
Keywords Efficiency
Language
Publication Year 2019
HGF-reported in Year 2019
ISSN (print) / ISBN 0144-8420
e-ISSN 1742-3406
Quellenangaben Volume: 185, Issue: 2, Pages: 222-230 Article Number: , Supplement: ,
Publisher Oxford University Press
Publishing Place Oxford
Reviewing status Peer reviewed
POF-Topic(s) 30504 - Mechanisms of Genetic and Environmental Influences on Health and Disease
Research field(s) Radiation Sciences
PSP Element(s) A-660200-001
PubMed ID 30668850
Erfassungsdatum 2019-03-07