PuSH - Publikationsserver des Helmholtz Zentrums München

Dreher, C.* ; Scholz, C.* ; Pommer, M.* ; Brons, S.* ; Prokesch, H.* ; Ecker, S.* ; Debus, J.* ; Jäkel, O.* ; Combs, S.E. ; Habermehl, D.

Optimization of carbon ion treatment plans by integrating tissue specific α/β-values for patients with non-resectable pancreatic cancer.

PLoS ONE 11:e0164473 (2016)
Verlagsversion Forschungsdaten DOI
Open Access Gold
Creative Commons Lizenzvertrag
Background: The aim of the thesis is to improve treatment plans of carbon ion irradiation by integrating the tissues' specific α/β-values for patients with locally advanced pancreatic cancer (LAPC). Material and Methods: Five patients with LAPC were included in this study. By the use of the treatment planning system Syngo RT Planning (Siemens, Erlangen, Germany) treatment plans with carbon ion beams have been created. Dose calculation was based on α/β-values for both organs at risk (OAR) and the tumor. Twenty-five treatment plans and thirty-five forward calculations were created. With reference to the anatomy five field configurations were included. Single Beam Optimization (SBO) and Intensity Modulated Particle Therapy (IMPT) were used for optimization. The plans were analyzed with respect to both dose distributions and individual anatomy. The plans were evaluated using a customized index. Results: With regard to the target, a field setup with one single posterior field achieves the highest score in our index. Field setups made up of three fields achieve good results in OAR sparing. Nevertheless, the field setup with one field is superior in complex topographic conditions. But, allocating an α/β-value of 2 Gy to the spinal cord leads to critical high maximum doses in the spinal cord. The evaluation of dose profiles showed significant dose peaks at borders of the α/β-gradient, especially in case of a single posterior field. Conclusion: Optimization with specific α/β-values allows a more accurate view on dose distribution than previously. A field setup with one single posterior field achieves good results in case of difficult topographic conditions, but leads to high maximum doses to the spinal cord. So, field setups with multiple fields seem to be more adequate in case of LAPC, being surrounded by highly radiosensitive normal tissues.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
3.057
1.044
6
5
Tags
Anmerkungen
Besondere Publikation
Auf Hompepage verbergern

Zusatzinfos bearbeiten
Eigene Tags bearbeiten
Privat
Eigene Anmerkung bearbeiten
Privat
Auf Publikationslisten für
Homepage nicht anzeigen
Als besondere Publikation
markieren
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Schlagwörter Neoadjuvant Chemoradiation; Dose Distribution; Radiotherapy; Therapy; Impact; Repair; Beams; Model; Trial
Sprache
Veröffentlichungsjahr 2016
HGF-Berichtsjahr 2016
ISSN (print) / ISBN 1932-6203
Zeitschrift PLoS ONE
Quellenangaben Band: 11, Heft: 10, Seiten: , Artikelnummer: e0164473 Supplement: ,
Verlag Public Library of Science (PLoS)
Verlagsort Lawrence, Kan.
Begutachtungsstatus Peer reviewed
POF Topic(s) 30203 - Molecular Targets and Therapies
Forschungsfeld(er) Radiation Sciences
PSP-Element(e) G-501300-001
Scopus ID 84991385258
Erfassungsdatum 2016-10-31