PuSH - Publikationsserver des Helmholtz Zentrums München

Sammer, M.* ; Zahnbrecher, E. ; Dobiasch, S. ; Girst, S.* ; Greubel, C.* ; Ilicic, K. ; Reindl, J.* ; Schwarz, B.* ; Siebenwirth, C.* ; Walsh, D.W.M.* ; Combs, S.E. ; Dollinger, G.* ; Schmid, T.E.

Proton pencil minibeam irradiation of an in-vivo mouse ear model spares healthy tissue dependent on beam size.

PLoS ONE 14:e0224873 (2019)
Verlagsversion Forschungsdaten DOI PMC
Open Access Gold
Creative Commons Lizenzvertrag
Proton radiotherapy using minibeams of sub-millimeter dimensions reduces side effects in comparison to conventional proton therapy due to spatial fractionation. Since the proton minibeams widen with depth, the homogeneous irradiation of a tumor can be ensured by adjusting the beam distances to tumor size and depth to maintain tumor control as in conventional proton therapy. The inherent advantages of protons in comparison to photons like a limited range that prevents a dosage of distal tissues are maintained by proton minibeams and can even be exploited for interlacing from different beam directions. A first animal study was conducted to systematically investigate and quantify the tissue-sparing effects of proton pencil minibeams as a function of beam size and dose distributions, using beam widths between s = 95, 199, 306, 411, 561 and 883 mu m (standard deviation) at a defined center-to-center beam distance (ctc) of 1.8 mm. The average dose of 60 Gy was distributed in 4x4 minibeams using 20 MeV protons (LET similar to 2.7 keV/mu m). The induced radiation toxicities were measured by visible skin reactions and ear swelling for 90 days after irradiation. The largest applied beam size to ctc ratio (s/ctc = 0.49) is similar to a homogeneous irradiation and leads to a significant 3-fold ear thickness increase compared to the control group. Erythema and desquamation was also increased significantly 3-4 weeks after irradiation. With decreasing beam sizes and thus decreasing s/ctc, the maximum skin reactions are strongly reduced until no ear swelling or other visible skin reactions should occur for s/ctc < 0.032 (extrapolated from data). These results demonstrate that proton pencil minibeam radiotherapy has better tissue-sparing for smaller s/ctc, corresponding to larger peak-to-valley dose ratios PVDR, with the best effect for s/ctc < 0.032. However, even quite large s/ctc (e.g. s/ctc = 0.23 or 0.31, i.e. PVDR = 10 or 2.7) show less acute side effects than a homogeneous dose distribution. This suggests that proton minibeam therapy spares healthy tissue not only in the skin but even for dose distributions appearing in deeper layers close to the tumor enhancing its benefits for clinical proton therapy.
Altmetric
Weitere Metriken?
Zusatzinfos bearbeiten [➜Einloggen]
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Korrespondenzautor
Schlagwörter Radiation-therapy; Radiotherapy; Optimization; Skin
ISSN (print) / ISBN 1932-6203
Zeitschrift PLoS ONE
Quellenangaben Band: 14, Heft: 11, Seiten: , Artikelnummer: e0224873 Supplement: ,
Verlag Public Library of Science (PLoS)
Verlagsort Lawrence, Kan.
Nichtpatentliteratur Publikationen